Isolated Walls Resting on Floating Floor

ISOLATED CEILINGS SUSPENDED BY RESILIENT HANGERS Scope Isolate masonry walls shown on drawings from building structure by supporting them on the floating concrete floor. Brace them with resilient sway braces and anchor the top by means of resiliently lined angle iron guides. Materials Wall Sway Braces: Double acting LDS sway braces with a fail safe…

Isolated Suspended Ceilings

PRODUCT DETAILS There are two types of resiliently suspended ceilings. The most common is a lightweight mechanical ceiling that contains the lighting fixtures, the outlets for the air conditioning system, etc. These lightweight ceilings consist of light steel framing drop-in absorptive tiles that are generally 24”x24” or 24”x36”. The primary purpose is to absorb sound…

LDS Form-work System for Roofs

PART 1 – GENERALPART 2 – PRODUCTSPART 3 – EXECUTIONPART 1 – GENERAL 1.01 Description Scope of Work Isolate floating roofs from the building structure by means of LDS isolators under plywood panels and perimeter isolation as shown on the drawings. If sound barrier walls are used, add the following: Build sound barrier walls on…

TV Studio, Theater LDS Form-work System

TYPICAL SLOPED THEATRE FLOOR LDS FORM-WORK SYSTEM FOR TV STUDIOS, THEATRES, BOWLING ALLEYS, KITCHEN, SQUASH COURTS, EXERCISE ROOMS, ETC. PART 1 – GENERALPART 2 – PRODUCTSPART 3 – EXECUTIONPART 1 – GENERAL 1.01 Description Scope of Work Isolate floating floors from building structure by means of LDS isolators under plywood panels and perimeter isolation in…

Mechanical Equipment LDS Form-work System

EAFM FLOATING FLOOR LDS FORM-WORK SYSTEM FOR MECHANICAL EQUIPMENT ROOMS WITH MACHINERY SUPPORTED BY THE FLOATING FLOOR. PART 1 – GENERALPART 2 – PRODUCTSPART 3 – EXECUTIONPART 1 – GENERAL 1.01 Description Scope of Work Isolate floating floors from building structure by means of jack-up LDS isolators and perimeter isolation in each of the mechanical…

TV Studio, Theater Spring Jack-up System

PART 1 – GENERALPART 2 – PRODUCTSPART 3 – EXECUTIONPART 1 – GENERAL 1.01 Description Scope of Work Isolate floating floors from the building structure by means of jack-up spring isolators and perimeter isolation in each of the ______________ rooms as shown on the drawings. (Architect to fill in name of room.) If sound barrier…

LDS Jack-up System for Roofs

PART 1 – GENERALPART 2 – PRODUCTSPART 3 – EXECUTIONPART 1 – GENERAL 1.01 Description Scope of Work Isolate floating roofs from the building structure by means of LDS isolators under plywood panels and perimeter isolation as shown on the drawings. If sound barrier walls are used, add the following: Build sound barrier walls on…

TV Studio, Theater LDS Jack-up System

TYPICAL FLOOR WITHOUT MACHINERY LDS JACK-UP SYSTEM FOR TV Studios, Theatres, Bowling Alleys, Kitchens, Squash Courts, Exercise Rooms, etc. PART 1 – GENERALPART 2 – PRODUCTSPART 3 – EXECUTIONPART 1 – GENERAL 1.01 Description We have left the blank below for you to fill in the name of the area, i.e. Auditorium, TV Studio, etc.…

Mechanical Equipment LDS Jack-up System

Mechanical Equipment LDS Jack-up System FLOATING FLOOR CONSTRUCTION SEQUENCE PLACEMENT OF ISOLATION MATERIALS POURING OF CONCRETE JACKED UP FLOATING FLOOR LDS JACK-UP SYSTEM FOR MECHANICAL EQUIPMENT ROOMS WITH MACHINERY SUPPORTED BY THE FLOATING FLOOR. PART 1 – GENERALPART 2 – PRODUCTSPART 3 – EXECUTIONPART 1 – GENERAL 1.01 Description Scope of Work Isolate floating floors…

Improved Performance

Improved Performance We started Mason Industries in 1958. Our revolutionary designs of high deflection free standing spring isolators, as opposed to housed mountings, and our literature with down to earth information made its mark. This generated phone calls from acoustical consultants asking us to get into the floating floor business. We asked why. In addition…